Operational Defect Database

BugZero found this defect 263 days ago.

Fortinet | 905795

Random FortiSwitch is shown as offline on the GUI when it is actually online.

Last update date:

5/11/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100F

FortiGate FG-101F

FortiGate FG-1100E

FortiGate FG-1101E

FortiGate FG-140E

FortiGate FG-140E-POE

FortiGate FG-1800F

FortiGate FG-1801F

Affected releases:

7.4.0

Fixed releases:

7.4.1

Description:

Random FortiSwitch is shown as offline on the GUI when it is actually online.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Fixed

Learn More

Search:

...