Operational Defect Database

BugZero found this defect 235 days ago.

Fortinet | 916903

When an HA management interface is configured, the GUI may not show the last interface entry in config system interface on several pages, such as the interface list, policy list, address list, and DNS servers page. This is a GUI-only display issue and does not impact the underlying operation of the affected interface.

Last update date:

5/11/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100E

FortiGate FG-100EF

FortiGate FG-100F

FortiGate FG-101E

FortiGate FG-101F

FortiGate FG-1100E

FortiGate FG-1101E

FortiGate FG-140E

Affected releases:

7.2.5

7.4.0

Fixed releases:

7.2.6

7.4.1

Description:

When an HA management interface is configured, the GUI may not show the last interface entry in config system interface on several pages, such as the interface list, policy list, address list, and DNS servers page. This is a GUI-only display issue and does not impact the underlying operation of the affected interface.Workaround: create a dummy interface to be the last entry in the config system interface table.config system interface edit set vdom "root" set status down set type loopback set snmp-index nextend