5/11/2023
FortiFirewall FFW-3980E
FortiFirewall FFW-VM64
FortiFirewall FFW-VM64-KVM
FortiGate FG-1000D
FortiGate FG-100E
FortiGate FG-100EF
FortiGate FG-100F
FortiGate FG-101E
FortiGate FG-101F
FortiGate FG-1100E
FortiGate FG-1101E
FortiGate FG-140E
7.2.5
7.4.0
7.2.6
7.4.1
When an HA management interface is configured, the GUI may not show the last interface entry in config system interface on several pages, such as the interface list, policy list, address list, and DNS servers page. This is a GUI-only display issue and does not impact the underlying operation of the affected interface.Workaround: create a dummy interface to be the last entry in the config system interface table.config system interface edit set vdom "root" set status down set type loopback set snmp-index nextend