Operational Defect Database

BugZero found this defect 263 days ago.

Fortinet | 919418

On the Policy & Objects > Firewall Policy page, when the interface name used in a virtual wire pair is a substring of interfaces used in a firewall policy, such policies are not displayed. For example, if a virtual wire pair consists of interfaces port1 and port2, firewall policies with port10, port11, port21, port22 are not displayed.

Last update date:

5/11/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100F

FortiGate FG-101F

FortiGate FG-1100E

FortiGate FG-1101E

FortiGate FG-140E

FortiGate FG-140E-POE

FortiGate FG-1800F

FortiGate FG-1801F

Affected releases:

7.4.0

Fixed releases:

7.4.1

Description:

On the Policy & Objects > Firewall Policy page, when the interface name used in a virtual wire pair is a substring of interfaces used in a firewall policy, such policies are not displayed. For example, if a virtual wire pair consists of interfaces port1 and port2, firewall policies with port10, port11, port21, port22 are not displayed.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Fixed

Learn More

Search:

...