BugZero found this defect 235 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/11/2023
FortiFirewall FFW-3980E
FortiFirewall FFW-VM64
FortiFirewall FFW-VM64-KVM
FortiGate FG-1000D
FortiGate FG-100E
FortiGate FG-100EF
FortiGate FG-100F
FortiGate FG-101E
FortiGate FG-101F
FortiGate FG-1100E
FortiGate FG-1101E
FortiGate FG-140E
7.2.5
7.4.0
7.2.6
7.4.1
SSL VPN service over PPPoE interface does not work as expected if the PPPoE interface is configured with config system pppoe-interface.config system pppoe-interface edit set device set username set password nextendconfig vpn ssl settings set source-interface endThis issue is also observed on VNE tunnel configurations.Workaround: configure the PPPoE interface with config system interface to allow the SSL VPN service to continue to work over the PPPoE interface.Delete the existing PPPoE interface and related configuration: config system pppoe-interface delete endConfigure the PPPoE interface under config system interface:config system interface edit set mode pppoe set username set password nextendApply this interface in the SSL VPN settings:config vpn ssl settings set source-interface end