System goes into halt state with Error: Package validation failed... message in cases where there are no engine files in the FortiGate when the BIOS security level is set to 2.

Last update date:

5/11/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100E

FortiGate FG-100EF

FortiGate FG-100F

FortiGate FG-101E

FortiGate FG-101F

FortiGate FG-1100E

Affected releases:

6.4.13

6.4.14

6.4.15

7.0.12

7.2.5

7.4.0

Fixed releases:

7.0.13

7.2.6

7.4.1

Description:

System goes into halt state with Error: Package validation failed... message in cases where there are no engine files in the FortiGate when the BIOS security level is set to 2.Workaround: set the BIOS security level to 0 or 1.