Operational Defect Database

BugZero found this defect 103 days ago.

Fortinet | 925130

If the FortiGate manages a FortiSwitch with a FortiSwitch port exported to a tenant VDOM, the Status dashboard on the tenant VDOM cannot load due to an issue with the Security Fabric widget. The loading issue may also impact the loading of subsequent pages.Workaround: remove the Security Fabric widget in the tenant VDOM's Status dashboard.

Last update date:

6/8/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100E

FortiGate FG-100EF

FortiGate FG-100F

FortiGate FG-101E

FortiGate FG-101F

FortiGate FG-1100E

Affected releases:

6.4.13

6.4.14

6.4.15

Fixed releases:

No fixed releases provided.

Description:

If the FortiGate manages a FortiSwitch with a FortiSwitch port exported to a tenant VDOM, the Status dashboard on the tenant VDOM cannot load due to an issue with the Security Fabric widget. The loading issue may also impact the loading of subsequent pages.Workaround: remove the Security Fabric widget in the tenant VDOM's Status dashboard.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Open

Learn More

Search:

...