ICMP reply packets are dropped by FortiOS in a NAT64 hyperscale policy.

Last update date:

8/31/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

FortiGate FG-100E

FortiGate FG-100EF

FortiGate FG-100F

FortiGate FG-101E

FortiGate FG-101F

FortiGate FG-1100E

Affected releases:

7.2.6

7.2.7

7.4.1

Fixed releases:

7.0.15

7.2.8

7.4.2

Description:

With NAT64 HS policy, ICMP reply packets are dropped by FortiOS. ICMP reply packets are dropped by FortiOS in a NAT64 hyperscale policy.