Administrator single sign-on login with SAML does not work after upgrading the firmware 7.4.1 due to the SAML entity-id field being incorrectly reset to being empty.

Last update date:

8/31/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-100F

FortiGate FG-101F

FortiGate FG-1100E

FortiGate FG-1101E

FortiGate FG-140E

FortiGate FG-140E-POE

FortiGate FG-1800F

FortiGate FG-1801F

Affected releases:

7.4.1

Fixed releases:

7.4.2

Description:

Administrator single sign-on login with SAML does not work after upgrading the firmware 7.4.1 due to the SAML entity-id field being incorrectly reset to being empty.Workaround: manually configure the entity-id field in the CLI to match with the previously working configuration.config system saml set entity-id end