Operational Defect Database

BugZero found this defect 67 days ago.

Fortinet | 950582

Traffic not passing across the VDOM link.

Last update date:

9/28/2023

Affected products:

FortiFirewall FFW-3980E

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

FortiGate FG-100E

FortiGate FG-100EF

FortiGate FG-100F

FortiGate FG-101E

FortiGate FG-101F

FortiGate FG-1100E

Affected releases:

7.2.6

7.2.7

Fixed releases:

7.2.8

7.4.2

Description:

Traffic not passing across the VDOM link.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Fixed

Learn More

Search:

...