When administrator GUI access (HTTPS) is enabled on SD-WAN member interfaces, the GUI may not be accessible on the SD-WAN interface due to incorrect routing of the response packet.

Last update date:

8/31/2023

Affected products:

FortiFirewall FFW-1801F

FortiFirewall FFW-2600F

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-4401F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

FortiGate FG-100F

Affected releases:

7.4.1

7.4.2

7.4.3

Fixed releases:

7.4.4

Description:

When administrator GUI access (HTTPS) is enabled on SD-WAN member interfaces, the GUI may not be accessible on the SD-WAN interface due to incorrect routing of the response packet.Workaround: access the GUI using another internal interface that is not part of an SD-WAN link.