Operational Defect Database

BugZero found this defect 5 days ago.

Fortinet | 973407

FIM installed NPU session causes the SSE to get stuck.

Last update date:

5/11/2023

Affected products:

FortiFirewall FFW-1801F

FortiFirewall FFW-2600F

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-4401F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

FortiGate FG-100E

Affected releases:

7.2.5

7.2.6

7.2.7

7.4.0

7.4.1

7.4.2

7.4.3

Fixed releases:

7.2.8

7.4.4

Description:

FIM installed NPU session causes the SSE to get stuck.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Fixed

Learn More

Search:

...