HPE ProLiant DL180 Gen9 Server
HPE ProLiant DL360 Gen9 Server
HPE ProLiant DL360e Gen8 Server
HPE ProLiant DL360p Gen8 SE Server
HPE ProLiant DL360p Gen8 Server
HPE ProLiant DL380 Gen9 Server
HPE ProLiant DL380e Gen8 Server
HPE ProLiant DL385p Gen8 Server
HPE ProLiant DL388 Gen9 Server
HPE ProLiant DL388e Gen8 Server
HPE ProLiant DL388p Gen8 Server
HPE ProLiant DL560 Gen8 Server
No affected releases provided.
No fixed releases provided.
On an HPE ProLiant server running the HPE SNMP Agents for Linux Version 10.60 (hp-snmp-agents), the following may occur: Files in directories under /var/spool/compaq/hpasm/registry/ have a Set Group ID up on execution (SGID) bit set that typically inherits permission from the user. This may cause security software to flag the agents due to the SGID bit set. AND When 32 128MB DIMMS are installed, the total memory displays "0MB" in System Management Homepage (SMH) -> System->System Board with SNMP Data Source. The operation or functionality of the server is not affected.
Any HPE ProLiant server running the hp-snmp-agents version 10.60.
This does not affect the operation or functionality of the server. This is targeted to be resolved in a future version of the hp-snmp-agents as follows: Files in directories under /var/spool/compaq/hpasm/registry/ will not have the SGID bit set And The SMH System Board page will display the actual memory installed instead of "0 MB." As a workaround, the memory installed in the server can be viewed using the following: Memory Subsystem page in SMH Power-On Self-Test (POST) Integrated Lights-Out (iLO) Operating System This advisory will be updated when additional information is available. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form. NAVIGATION TIP : For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document . SEARCH TIP : For hints on locating similar documents on HPE.com, refer to the Search Tips document . To search for additional advisories related to iLO, use the following search string: +Advisory +ProLiant -"Software and Drivers" +iLO