Operational Defect Database

BugZero found this defect 978 days ago.

Hewlett Packard Enterprise | a00118281en_us

Advisory: Pensando Distributed Services Platform DSC Card - Incorrect HPE Integrated Lights-Out 5 (iLO 5) NIC Information and Integrated Management Log (IML) Events for Pensando Distributed Services Platform DSC Card with HPE Agentless Management Service

Last update date:

2/29/2024

Affected products:

Pensando Offerings

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

On an HPE system, prior to booting OS and without HPE Agentless Management Service (AMS) running, the HPE Integrated Lights-Out 5 (iLO 5) Integrated Management Log (IML) displays the expected link events for Port 1 and Port 2 of the Pensando Distributed Services Platform DSC card. However, after AMS is installed and running, all of the following occur: With firmware version 1.14.2, Pensando Distributed Services Platform DSC-25 Enterprise 10/25Gb 2-port SFP28 Card is recognized as duplicate devices and is displayed two times as "Port 1" in iLO 5 Although the IML events continue to be unique (not stacked), the text for the events displays "Port 1" regardless if the specific event was applicable to Port 2. The information displayed on the iLO 5 SystemInformation->NIC Information page also displays both ports as "Port 1" although it does display the unique MAC address for each. IML does not report certain Pensando Distributed Services Platform DSC card events for example, when removing/reinserting cable on single port. Only the removal events are displayed and the restore state is not displayed.

Scope

Any HPE system running AMS and configured with any of the following Pensando Distributed Services Platform DSC cards: Pensando Distributed Services Platform DSC-100 Enterprise 100Gb 2-port QSFP28 Card Pensando Distributed Services Platform DSC-25 10/25Gb 2-port SFP28 Card Pensando Distributed Services Platform for HPE iLO Sideband Management Adaptive LOM Module This is non-OS specific.

Resolution

As a workaround, use the following: When AMS is not running, the iLO 5 IML events and iLO 5 NIC information will function as expected. The iLO 5 Integration CPLD register that is communicating the link status from the Pensando Distributed Services Platform DSC card to iLO 5 over i2c reports the correct link status for Port 1 and Port 2. AMS is interpreting both ports as "Port 1" and reporting "Port 1" to iLO 5. However, the MAC address displays unique and can be used to identify the ports. For the iLO 5 incorrect NIC information, instead of viewing the IML for removing/reinserting cable events, refer to the OS logs or view the physical LED indication. This advisory will be updated if additional information becomes available. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form. NAVIGATION TIP : For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for HPE systems and Options, refer to the Navigation Tips document . SEARCH TIP : For hints on locating similar documents on HPE.com, refer to the Search Tips Document . To search for additional advisories related to Pensando Distributed Services Platform DSC cards, use the following search string: +Advisory +ProLiant -"Software and Drivers" +Pensando Distributed Services Platform DSC cards

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...