Operational Defect Database

BugZero found this defect 319 days ago.

Hewlett Packard Enterprise | a00133629en_us

Advisory: Critical ClusterStor 6.4-010 Alert

Last update date:

1/12/2024

Affected products:

Cray CLS E1000 Storage Systems

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

A critical bug has been discovered in 6.4-010 which could impact system stability. The bug is specific to Lustre quotas.

Scope

If a ClusterStor E1000 is upgraded to 6.4-010 and quota enforcement is enabled, there is a possibility of mds node panics which may lead to a system outage

Resolution

A fix for this 6.4-010 bug is being tested now and will be available in 6.4-020. The target release of 6.4-020 is the end of July. If you require 6.4-010, please ensure Lustre quota enforcement is disabled until your system is upgraded to 6.4-020.