Operational Defect Database

BugZero found this defect 124 days ago.

Hewlett Packard Enterprise | a00136131en_us

Advisory: (Revision) HPE OneView 8.60 - The "iLO Settings Do Not Match the Expected Values" Alert Message May Initially Remain When the Server Profile Is Re-Applied

Last update date:

1/18/2024

Affected products:

HPE OneView

Affected releases:

HPE OneView

Fixed releases:

No fixed releases provided.

Description:

Info

Document Version Release Date Details 2 January 17, 2024 Updated the Resolution with the permanent fix, OneView 8.7. 1 November 22, 2023 Original Document Release. When re-applying a server profile that contains iLO settings, the following alert may not immediately clear as part of the server profile re-apply action: " iLO Settings do not match the expected values. Resolution Reapply the server profile to configure the iLO settings to match the expected values ." The alert may take several minutes to clear after the server profile reapply.

Scope

HPE OneView 8.60.

Resolution

This issue is resolved in HPE OneView 8.7. Update to OneView 8.7 or later. A workaround is to clear the alert manually if waiting a few minutes is not an option. OR Wait for the alert to clear after the server profile is reapplied. The alert may take several minutes after it is reapplied. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...