Operational Defect Database

BugZero found this defect 152 days ago.

Hewlett Packard Enterprise | a00136664en_us

Advisory: HPE iLO 6 - HPE Computes That Had iLO 6 Firmware Version 1.54 Installed, the iLO May No Longer Post Events to HPE OneView, HPE Compute Operation Management or Other Redfish-Based Monitoring Software

Last update date:

2/6/2024

Affected products:

HPE ProLiant DL110 Gen11

HPE ProLiant DL20 Gen11

HPE ProLiant DL320 Gen11

HPE ProLiant DL325 Gen11

HPE ProLiant DL345 Gen11

HPE ProLiant DL360 Gen11

HPE ProLiant DL365 Gen11

HPE ProLiant DL380 Gen11

HPE ProLiant DL380a Gen11

HPE ProLiant DL385 Gen11

HPE ProLiant DL560 Gen11

HPE ProLiant DX325 Gen11

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

If the iLO firmware version 1.54 has ever been installed on any HPE Computes with HPE Integrated Lights-Out 6 (iLO 6), this version of the iLO firmware may have over-written the iLO Redfish Event Subscriptions entries. This can prevent monitoring software from receiving life-cycle events or hardware alert messages.

Scope

HPE Integrated Lights-Out (iLO 6) firmware version 1.54.

Resolution

For any iLO 6 host that has ever had iLO version 1.54 installed, perform the following actions: NOTE : Skip the following steps if the iLO 6 firmware was updated directly from 1.53 (or earlier) to version 1.55 or later. Update the iLO 6 to version 1.55 or later. On each of iLO 6 that once ran version 1.54, perform an iLO Redfish call to clear all the iLO’s subscriptions: POST /redfish/v1/EventService/Actions/Oem/Hpe/HpeEventService.ClearAllSubscriptions/ Verify this API returns 200 OK Perform "Reset iLO" as an iLO reset is required HPE OneView HPE OneView will automatically recover from this condition after 8 hours of not receiving any health events from iLO 6. Alternatively, perform a Server Hardware refresh, or a Logical Enclosure refresh for enclosure-based environments. HPE Compute Ops Management (COM) To recover in COM, use both options and perform the following steps: Option 1 On environments with access to the network switch where the iLO 6 network port is connected to, perform the following steps on that network switch port: Disable the network port. Leave the port down for 2 minutes. Enable the network port. Option 2 On the iLO Management -> Compute Ops Management section: Disable Compute Ops Management within iLO. Leave disconnected for 2 minutes. Enable Compute Ops Management within iLO. NOTE : Both option 1 and option 2 may be automated by using the respective scripting technologies. For Other Monitoring Software Reference the vendor's monitoring software documentation on how to re-establish the Redfish subscription. To determine the hardware status of each computes, reference the iLO's IML tab to find any current warning or critical events. This process may be automated by iLO's Redfish API, HPE iLO cmdlets for PowerShell, or HPE RESTful Interface tool. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center. NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document.