HPE Apollo 2000 Gen10 Plus System
HPE Apollo 6500 Gen10 Plus System
HPE Apollo 6500 Gen10 System
HPE Cloudline CL2100 Gen10 Server
HPE Cloudline CL2200 Gen10 Server
HPE Cloudline CL2600 Gen10 Server
HPE Cloudline CL2800 Gen10 Server
HPE Cloudline CL3100 Gen10 Server
HPE Cloudline CL3150 Gen10 Server
HPE Cloudline CL4100 Gen10 Server
HPE Cloudline CL4150 Gen10 Server
HPE Cloudline CL4300 Gen10 Server
HPE OneView
No fixed releases provided.
The HPE Integrated Lights-Out 5 and HPE Integrated Lights-Out 6 (iLO 5, iLO 6) do not support Cipher Suite 17 for the Intelligent Platform Management Interface (IPMI). For instance, running the "ipmitool" utility version 1.8.18 with the interface specifed as "lanplus" and cipher suite as "17" for an iLO 5 or iLO 6 will result in the following error, "Error in open session response message : no matching cipher suite Error: Unable to establish IPMI v2 / RMCP+ session."
HPE Integrated Lights-Out 5 and 6.
The Support for Cipher Suite 17 for the Intelligent Platform Management Interface (IPMI) will be added in a future release of the iLO 5 and iLO 6 firmware. This advisory will be updated when additional information becomes available.