Operational Defect Database

BugZero found this defect 125 days ago.

Hewlett Packard Enterprise | a00137012en_us

Advisory: HPE Edgeline - A "Halted System Due to SPDM Component Authentication Failure" Message May Appear on the Console After the Power-On Self-Test

Last update date:

1/16/2024

Affected products:

HPE Compute Edge Server e930t

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

On an HPE Compute Edge Server e930t, "Halted system due to SPDM component authentication failure" message may be seen on the console after the Power-On Self-Test (POST) is complete, and the system will not continue to boot. The Compute Edge Server e930t uses the Security Protocol and Data Model (SPDM) to verify the integrity of components and authenticate the supported option cards. If this issue occurs, the Channel Interface (CHIF) driver interface has caused the server's processing to time out after POST.

Scope

Any HPE Compute Edge Server e930t.

Resolution

This issue will be corrected in a future maintenance release for HPE Edgeline. As a workaround, reboot the system to recover. This advisory will be updated when additional solutions become available. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: HPE Email Preference Center. NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...