Advisory: HPE Compute Edge Server e930t - The Embedded NIC "BCM5720 " May No Longer Be Displayed After VROC Is Enabled

Last update date:

3/4/2024

Affected products:

HPE Compute Edge Server e930t

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

After enabling VROC on an HPE Compute Edge Server e930t, the embedded NIC, "BCM5720" may no longer be displayed in the operating system.

Scope

Any HPE Compute Edge Server e930t in the scenario described above.

Resolution

If it is intended to use VROC on this system, install other optional NIC cards instead of using the embedded NIC. VROC does not function with the embedded NIC. This advisory will be updated if additional solutions become available.