Operational Defect Database

BugZero found this defect 4501 days ago.

Hewlett Packard Enterprise | c03122753

HPSBUX02730 SSRT100710 rev.1 - HP-UX Running Java, Remote Unauthorized Access, Disclosure of Information, and Other Vulnerabilities

Last update date:

2/14/2024

Affected products:

HP-UX Java Software

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

Document ID: c03122753 Version: 1 HPSBUX02730 SSRT100710 rev.1 - HP-UX Running Java, Remote Unauthorized Access, Disclosure of Information, and Other Vulnerabilities NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2011-12-15 Last Updated: 2012-01-23 Potential Security Impact: Remote unauthorized access, disclosure of information, and other vulnerabilities Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY Potential security vulnerabilities have been identified in Java Runtime Environment (JRE) and Java Developer Kit (JDK) running on HP-UX. These vulnerabilities could allow remote unauthorized access, disclosure of information, and other vulnerabilities. References: CVE-2011-3389, CVE-2011-3516, CVE-2011-3521, CVE-2011-3544, CVE-2011-3545, CVE-2011-3546, CVE-2011-3547, CVE-2011-3548, CVE-2011-3549, CVE-2011-3550, CVE-2011-3551, CVE-2011-3552, CVE-2011-3553, CVE-2011-3554, CVE-2011-3556, CVE-2011-3557, CVE-2011-3558, CVE-2011-3560, CVE-2011-3561. SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HP-UX B.11.11, B.11.23, B.11.31 running HP JDK and JRE 6.0.12 or earlier BACKGROUND CVSS 2.0 Base Metrics Reference and Affectivity Base Vector Base Score CVE-2011-3389 (AV:N/AC:M/Au:N/C:P/I:N/A:N) 4.3 CVE-2011-3516 (AV:N/AC:H/Au:N/C:C/I:C/A:C) 7.6 CVE-2011-3521 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3544 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3545 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3546 (AV:N/AC:M/Au:N/C:P/I:P/A:N) 5.8 CVE-2011-3547 (AV:N/AC:L/Au:N/C:P/I:N/A:N) 5.0 CVE-2011-3548 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3549 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3550 (AV:N/AC:H/Au:N/C:C/I:C/A:C) 7.6 CVE-2011-3551 (AV:N/AC:M/Au:N/C:C/I:C/A:C) 9.3 CVE-2011-3552 (AV:N/AC:H/Au:N/C:N/I:P/A:N) 2.6 CVE-2011-3553 (AV:N/AC:M/Au:S/C:P/I:N/A:N) 3.5 CVE-2011-3554 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2011-3556 (AV:N/AC:L/Au:N/C:P/I:P/A:P) 7.5 CVE-2011-3557 (AV:N/AC:M/Au:N/C:P/I:P/A:P) 6.8 CVE-2011-3558 (AV:N/AC:L/Au:N/C:P/I:N/A:N) 5.0 CVE-2011-3560 (AV:N/AC:L/Au:N/C:P/I:P/A:N) 6.4 CVE-2011-3561 (AV:A/AC:H/Au:N/C:P/I:N/A:N) 1.8 Information on CVSS is documented in HP Customer Notice: HPSN-2008-002 RESOLUTION HP has provided the following Java version upgrades to resolve these vulnerabilities. This bulletin will be revised as other upgrades for additional supported Java versions become available. The upgrades are available from the following location http://www.hp.com/go/java HP-UX B.11.11, B.11.23, B.11.31 JDK and JRE v6.0.13 or subsequent MANUAL ACTIONS: Yes - Update For Java v6.0.12 and earlier, update to Java v6.0.13 or subsequent PRODUCT SPECIFIC INFORMATION HP-UX Software Assistant: HP-UX Software Assistant is an enhanced application that replaces HP-UX Security Patch Check. It analyzes all Security Bulletins issued by HP and lists recommended actions that may apply to a specific HP-UX system. It can also download patches and create a depot automatically. For more information see https://www.hp.com/go/swa The following text is for use by the HP-UX Software Assistant. AFFECTED VERSIONS HP-UX B.11.11 HP-UX B.11.23 HP-UX B.11.31 =========== Jre60.JRE60-COM Jre60.JRE60-IPF32 Jre60.JRE60-IPF32-HS Jre60.JRE60-IPF64 Jre60.JRE60-IPF64-HS Jre60.JRE60-PA20 Jre60.JRE60-PA20-HS Jre60.JRE60-PA20W Jre60.JRE60-PA20W-HS Jdk60.JDK60-COM Jdk60.JDK60-IPF32 Jdk60.JDK60-IPF64 Jdk60.JDK60-PA20 Jdk60.JDK60-PA20W action: install revision 1.6.0.13.00 or subsequent END AFFECTED VERSIONS HISTORY Version:1 (rev.1) 23 January 2012 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer's patch management policy. Support: For further information, contact normal HP Services support channel. Report: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com Subscribe: To initiate a subscription to receive future HP Security Bulletin alerts via Email: http://h41183.www4.hp.com/signup_alerts.php?jumpid=hpsc_secbulletins Security Bulletin List: A list of HP Security Bulletins, updated periodically, is contained in HP Security Notice HPSN-2011-001 https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c02964430 Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://h20566.www2.hp.com/portal/site/hpsc/public/kb/secBullArchive/ Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB. 3C = 3COM 3P = 3rd Party Software GN = HP General Software HF = HP Hardware and Firmware MP = MPE/iX MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PI = Printing and Imaging PV = ProCurve ST = Storage Software TU = Tru64 UNIX UX = HP-UX System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HP has provided the following Java version upgrades to resolve these vulnerabilities. This bulletin will be revised as other upgrades for additional supported Java versions become available. The upgrades are available from the following location http://www.hp.com/go/java HP-UX B.11.11, B.11.23, B.11.31 JDK and JRE v6.0.13 or subsequent MANUAL ACTIONS: Yes - Update For Java v6.0.12 and earlier, update to Java v6.0.13 or subsequent PRODUCT SPECIFIC INFORMATION HP-UX Software Assistant: HP-UX Software Assistant is an enhanced application that replaces HP-UX Security Patch Check. It analyzes all Security Bulletins issued by HP and lists recommended actions that may apply to a specific HP-UX system. It can also download patches and create a depot automatically. For more information see https://www.hp.com/go/swa The following text is for use by the HP-UX Software Assistant. AFFECTED VERSIONS HP-UX B.11.11 HP-UX B.11.23 HP-UX B.11.31 =========== Jre60.JRE60-COM Jre60.JRE60-IPF32 Jre60.JRE60-IPF32-HS Jre60.JRE60-IPF64 Jre60.JRE60-IPF64-HS Jre60.JRE60-PA20 Jre60.JRE60-PA20-HS Jre60.JRE60-PA20W Jre60.JRE60-PA20W-HS Jdk60.JDK60-COM Jdk60.JDK60-IPF32 Jdk60.JDK60-IPF64 Jdk60.JDK60-PA20 Jdk60.JDK60-PA20W action: install revision 1.6.0.13.00 or subsequent END AFFECTED VERSIONS HISTORY Version:1 (rev.1) 23 January 2012 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer's patch management policy. Support: For further information, contact normal HP Services support channel. Report: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com Subscribe: To initiate a subscription to receive future HP Security Bulletin alerts via Email: http://h41183.www4.hp.com/signup_alerts.php?jumpid=hpsc_secbulletins Security Bulletin List: A list of HP Security Bulletins, updated periodically, is contained in HP Security Notice HPSN-2011-001 https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c02964430 Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://h20566.www2.hp.com/portal/site/hpsc/public/kb/secBullArchive/ Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB. 3C = 3COM 3P = 3rd Party Software GN = HP General Software HF = HP Hardware and Firmware MP = MPE/iX MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PI = Printing and Imaging PV = ProCurve ST = Storage Software TU = Tru64 UNIX UX = HP-UX

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...