Operational Defect Database

BugZero found this defect 3379 days ago.

Hewlett Packard Enterprise | c04573026

Advisory: HP 6120XG and 6120G/XG Ethernet Blade Switch May Display the Message, "Sorry, the Maximum Number of Telnet Sessions Are Active. Try Again Later" When Attempting to Telnet to the Management Interface

Last update date:

2/13/2024

Affected products:

HPE 6120XG Ethernet Blade Switch

HPE Integrity BL860c Server Blade

HPE Integrity BL860c i2 Server Blade

HPE Integrity BL870c Server Blade

HPE Integrity BL870c i2 Server Blade

HPE Integrity BL890c i2 Server Blade

HPE ProLiant BL260c G5 Server Blade

HPE ProLiant BL280c G6 Server Blade

HPE ProLiant BL2x220c G5 Server Blade

HPE ProLiant BL2x220c G6 Server Blade

HPE ProLiant BL420c Gen8 Server Blade

HPE ProLiant BL460c G5 Server Blade

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

On an HP c-Class BladeSystem, an HP 6120XG and 6120G/XG Ethernet Blade Switch Telnet and/or SSH sessions may become unresponsive and require a reboot to become available again. While in this condition, Telnet and/or SSH connection attempts will receive a message similar to the following: Sorry, the maximum number of telnet sessions are active. Try again later.

Scope

Any HP c-Class BladeSystem configured with an HP 6120XG or 6120G/XG \Ethernet Blade Switch running Firmware Version Z.14.50 (or earlier).

Resolution

To correct this issue, update the switch firmware to HP ProCurve 6120 Blade Switch Firmware Version Z.14.51 (or later). http://h20564.www2.hp.com/hpsc/swd/public/detail?swItemId=MTX_ef58fd6a93e34c8a8a996ece03 As a workaround, reboot the switch. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: http://www.hp.com/go/myadvisory NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document . SEARCH TIP : For hints on locating similar documents on HP.com, refer to the Search Tips document

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...