Operational Defect Database

BugZero found this defect 1497 days ago.

Hewlett Packard Enterprise | hpesbhf03912en_us

HPESBHF03912 rev.3 - Certain HPE Servers and StoreEasy Appliances with a UEFI-based BIOS, Multiple Local Vulnerabilities

Last update date:

3/14/2024

Affected products:

HPE Apollo 2000 System

HPE ProLiant BL460c Gen10 Server Blade

HPE ProLiant BL460c Gen9 Server Blade

HPE ProLiant BL660c Gen9 Server Blade

HPE ProLiant DL120 Gen10 Server

HPE ProLiant DL120 Gen9 Server

HPE ProLiant DL160 Gen10 server

HPE ProLiant DL160 Gen9 Server

HPE ProLiant DL180 Gen10 server

HPE ProLiant DL180 Gen9 Server

HPE ProLiant DL20 Gen10 server

HPE ProLiant DL20 Gen9 Server

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

Document ID: hpesbhf03912en_us Version: 3 HPESBHF03912 rev.3 - Certain HPE Servers and StoreEasy Appliances with a UEFI-based BIOS, Multiple Local Vulnerabilities NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2019-04-03 Last Updated: 2020-04-14 Potential Security Impact: Local: Denial of Service (DoS), Disclosure of Information, Escalation of Privilege Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY Security vulnerabilities in UEFI Open Source (EDK2)-based BIOS firmware may allow escalation of privilege, information disclosure or denial of service. Vendors are releasing firmware updates to mitigate these vulnerabilities. References: CVE-2018-12201 CVE-2018-12202 CVE-2018-12203 CVE-2018-12204 CVE-2018-12205 CVE-2017-5731 CVE-2017-5732 CVE-2017-5733 CVE-2017-5734 CVE-2017-5735 CVE-2018-12178 CVE-2018-12179 CVE-2018-12180 CVE-2018-12181 CVE-2018-12182 CVE-2018-12183 CVE-2018-3613 CVE-2018-3630 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HPE ProLiant DL380 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL360 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL180 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL160 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL120 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant XL170r Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant XL190r Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant XL230k Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant XL270d Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant XL450 Gen10 Server Prior to v2.02 3/19/19 HPE Apollo 2000 System Prior to v2.02 3/19/19 HPE Apollo 4200 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL560 Gen10 Server Prior to v2.02 3/19/19 HPE ProLiant DL580 Gen10 Server Prior to v2.02 3/19/19 HPE Synergy 480 Gen10 Compute Module Prior to v2.02 3/19/19 HPE Synergy 660 Gen10 Compute Module Prior to v2.02 3/19/19 HPE ProLiant BL460c Gen10 Server Blade Prior to v2.02 3/19/19 HPE ProLiant DL20 Gen10 Server Prior to v1.20 02/02/2019 HPE ProLiant ML30 Gen10 Server Prior to v1.20 02/02/2019 HPE ProLiant ML30 Gen9 Server Prior to v2.80 12/18/2018 HPE ProLiant DL20 Gen9 Server Prior to v2.80 12/18/2018 HPE Synergy 680 Gen9 Compute Module Prior to v2.70 12/29/2018 HPE Synergy 660 Gen9 Compute Module Prior to v2.70 12/29/2018 HPE Synergy 620 Gen9 Compute Module Prior to v2.70 12/29/2018 HPE Synergy 480 Gen9 Compute Module Prior to v2.70 12/29/2018 HPE ProLiant DL580 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant BL660c Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant WS460c Gen9 Graphics Server Blade Prior to v2.70 12/29/2018 HPE ProLiant BL460c Gen9 Server Blade Prior to v2.70 12/29/2018 HPE ProLiant ML110 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant ML150 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant ML350 Gen9 Server Prior to v2.70 12/29/2018 HP ProLiant DL360 Gen9 Server Prior to v2.70 12/29/2018 HP ProLiant DL380 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL120 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL560 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL270d Gen9 Accelerator Tray 2U Configure-to-order Server Prior to v2.70 12/29/2018 HPE ProLiant XL450 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL180 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL160 Gen9 Server Prior to v2.70 12/29/2018 HPE Apollo 4200 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL750f Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL740f Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL730f Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL80 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant DL60 Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL250a Gen9 Server Prior to v2.70 12/29/2018 HPE ProLiant XL230a Gen9 Server Prior to v2.70 12/29/2018 HPE Storage File Controllers HPE Storage File Controller and Storage Performance File Controller HPE StoreEasy 1000 Storage 1460, 1560, 1660, 1660 Performance, 1860, 1860 Performance, BACKGROUND CVSS Version 3.0 and Version 2.0 Base Metrics Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2017-5731 CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2017-5732 CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2017-5733 CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2017-5734 CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2017-5735 CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2018-12178 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 9.1 (AV:N/AC:L/Au:N/C:N/I:C/A:C) 9.4 CVE-2018-12179 CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 7.8 (AV:L/AC:L/Au:N/C:P/I:P/A:P) 4.6 CVE-2018-12180 CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 8.8 (AV:N/AC:M/Au:N/C:P/I:P/A:P) 6.8 CVE-2018-12181 CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H 6.0 (AV:L/AC:L/Au:N/C:N/I:P/A:P) 3.6 CVE-2018-12182 CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H 6.7 (AV:L/AC:L/Au:N/C:P/I:P/A:P) 4.6 CVE-2018-12183 CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 6.8 (AV:L/AC:L/Au:N/C:P/I:P/A:P) 4.6 CVE-2018-12201 CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H 5.7 (AV:L/AC:H/Au:N/C:N/I:C/A:C) 5.6 CVE-2018-12202 CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H 5.7 (AV:L/AC:H/Au:N/C:N/I:C/A:C) 5.6 CVE-2018-12203 CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L 2.3 (AV:L/AC:L/Au:N/C:N/I:N/A:P) 2.1 CVE-2018-12204 CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H 7.1 (AV:L/AC:H/Au:N/C:C/I:C/A:C) 6.2 CVE-2018-12205 CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 7.6 (AV:L/AC:L/Au:N/C:C/I:C/A:C) 7.2 CVE-2018-3613 CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 7.8 (AV:L/AC:L/Au:N/C:P/I:P/A:P) 4.6 CVE-2018-3630 CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 7.6 (AV:L/AC:L/Au:N/C:C/I:C/A:C) 7.2 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 RESOLUTION HPE has provided firmware updates for all of the above listed products. Please visit HPE Support Center https://support.hpe.com/hpesc/public/home to obtain the updated firmware for your product. HISTORY Version:1 (rev.1) - 3 April 2019 Initial release Version:2 (rev.2) - 10 April 2019 Added Tianocore UEFI CVEs, removed AMD processor-based servers Version:3 (rev.3) - 14 April 2020 Added StoreEasy Products Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HPE has provided firmware updates for all of the above listed products. Please visit HPE Support Center https://support.hpe.com/hpesc/public/home to obtain the updated firmware for your product. HISTORY Version:1 (rev.1) - 3 April 2019 Initial release Version:2 (rev.2) - 10 April 2019 Added Tianocore UEFI CVEs, removed AMD processor-based servers Version:3 (rev.3) - 14 April 2020 Added StoreEasy Products Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive