Hewlett Packard Enterprise | hpesbhf04103en_us

HPESBHF04103 rev.1 - HPE Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5) or Integrated Lights-Out 4 (iLO 4), Ripple20 Multiple Vulnerabilities

Last update date:

2/8/2024

Affected products:

HPE Synergy 480 Gen10 Compute Module

HPE Synergy 480 Gen9 Compute Module

HPE Synergy 660 Gen10 Compute Module

HPE Integrated Lights-Out 4 (iLO 4)

HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

Document ID: hpesbhf04103en_us Version: 1 HPESBHF04103 rev.1 - HPE Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5) or Integrated Lights-Out 4 (iLO 4), Ripple20 Multiple Vulnerabilities NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2021-03-24 Last Updated: 2021-03-25 Potential Security Impact: Remote: Code Execution, Denial of Service (DoS), Disclosure of Sensitive Information, Multiple Vulnerabilities Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY Multiple security vulnerabilities have been identified in Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerabilities could be remotely exploited to execute code, cause denial of service, and expose sensitive information. HPE has released updated firmware to mitigate these vulnerabilities. Note: These vulnerabilities are collectively named Ripple20. iLO 5 and iLO 4 are only exposed to a portion of the Ripple20 vulnerabilities. HPE has modified the reported Ripple20 CVSS scores and vectors to reflect product engineering's vulnerability assessment. References: CVE-2020-11896 CVE-2020-11898 CVE-2020-11900 CVE-2020-11906 CVE-2020-11907 CVE-2020-11911 CVE-2020-11912 CVE-2020-11914 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers -Prior to v2.18 - (Please see the RESOLUTION note) HPE Integrated Lights-Out 4 (iLO 4) -Prior to v2.75 - (Please see the RESOLUTION note) HPE Synergy 660 Gen10 Compute Module -Prior HPE Synergy Custom SPP 2020.05.02 HPE Synergy 480 Gen10 Compute Module -Prior HPE Synergy Custom SPP 2020.05.02 HPE Synergy 480 Gen9 Compute Module -Prior HPE Synergy Custom SPP 2020.05.02 BACKGROUND HPE calculates CVSS using CVSS Version 3.1. If the score is provided from NIST, we will display Version 2.0, 3.0, or 3.1 as provided from NVD. Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2020-11896 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H 8.2 (AV:N/AC:L/Au:N/C:N/I:P/A:C) 8.5 CVE-2020-11898 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 7.5 (AV:N/AC:L/Au:N/C:C/I:N/A:N) 7.8 CVE-2020-11900 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) 10.0 CVE-2020-11906 CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H 6.4 (AV:A/AC:H/Au:N/C:P/I:P/A:C) 5.8 CVE-2020-11907 CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H 5.9 (AV:A/AC:H/Au:N/C:N/I:P/A:C) 5.3 CVE-2020-11911 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L 3.7 (AV:N/AC:H/Au:N/C:N/I:N/A:P) 2.6 CVE-2020-11912 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N 3.7 (AV:N/AC:H/Au:N/C:P/I:N/A:N) 2.6 CVE-2020-11914 CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N 3.1 (AV:A/AC:H/Au:N/C:P/I:N/A:N) 1.8 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 HPE would like to thank JSOF security researchers Shlomi Oberman and Moshe Kol for reporting these vulnerabilities to CERT. HPE would like to thank CERT for reporting these vulnerabilities to security-alert@hpe.com. RESOLUTION HPE has released a firmware update to resolve the vulnerabilities in Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). Please see the Synergy Software Release Information for release details and links to download the latest HPE Synergy Custom SPP: HPE Synergy Custom SPP 2020.05.02 or later. iLO 5 v2.18 or later. iLO 4 v2.75 or later. Note: iLO 5 v2.18 and iLO 4 2.75 are delivered in the HPE Synergy Custom SPP 2020.05.02 release. HISTORY Version:1 (rev.1) - 24 March 2021 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HPE has released a firmware update to resolve the vulnerabilities in Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). Please see the Synergy Software Release Information for release details and links to download the latest HPE Synergy Custom SPP: HPE Synergy Custom SPP 2020.05.02 or later. iLO 5 v2.18 or later. iLO 4 v2.75 or later. Note: iLO 5 v2.18 and iLO 4 2.75 are delivered in the HPE Synergy Custom SPP 2020.05.02 release. HISTORY Version:1 (rev.1) - 24 March 2021 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive