Operational Defect Database

BugZero found this defect 434 days ago.

Hewlett Packard Enterprise | hpesbhf04456en_us

HPESBHF04456 rev.1 - HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4), Remote Cross-Site Scripting

Last update date:

2/23/2024

Affected products:

HPE Apollo 2000 Gen10 Plus System

HPE Apollo 6500 Gen10 Plus System

HPE Apollo 6500 Gen10 System

HPE Apollo r2000 Chassis

HPE Edgeline e920 Server Blade

HPE Edgeline e920d Server Blade

HPE Edgeline e920t Server Blade

HPE ProLiant BL420c Gen8 Server Blade

HPE ProLiant BL460c Gen10 Server Blade

HPE ProLiant BL460c Gen8 Server Blade

HPE ProLiant BL460c Gen9 Server Blade

HPE ProLiant BL465c Gen8 Server Blade

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

Document ID: hpesbhf04456en_us Version: 1 HPESBHF04456 rev.1 - HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4), Remote Cross-Site Scripting NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2023-03-13 Last Updated: 2023-03-13 Potential Security Impact: Remote: Cross-Site Scripting (XSS) Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY A potential security vulnerability has been identified in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). The vulnerability could be remotely exploited to allow stored Cross-Site scripting attack. References: CVE-2023-28083 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HPE Integrated Lights-Out 4 (iLO 4) - Prior to v2.82 HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers - Prior to v2.78 HPE Integrated Lights-Out 6 (iLO 6) - Prior to v1.20 HPE ProLiant DL320 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL325 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL345 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL360 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL365 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL380 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DL385 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant ML350 Gen11 Server - Prior to iLO 6 v1.20 HPE ProLiant DX380 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DX385 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DX220n Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DX360 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DX385 Gen10 Plus v2 server - Prior to iLO 5 v2.78 HPE ProLiant DX325 Gen10 Plus v2 server - Prior to iLO 5 v2.78 HPE ProLiant DX4200 Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DX560 Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DX380 Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DX360 Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DX170r Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DX190r Gen10 server - Prior to iLO 5 v2.78 HPE ProLiant DL20 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant ML30 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant ML110 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant ML350 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL325 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL360 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL345 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL365 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL385 Gen10 Plus v2 server - Prior to iLO 5 v2.78 HPE ProLiant DL380 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL385 Gen10 Plus server - Prior to iLO 5 v2.78 HPE ProLiant DL20 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL120 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL160 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL180 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL325 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL360 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL380 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL385 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL580 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant DL560 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant BL460c Gen10 Server Blade - Prior to iLO 5 v2.78 HPE Synergy 680 Gen9 Compute Module - Prior to iLO 4 v2.82 HPE Synergy 660 Gen9 Compute Module - Prior to iLO 4 v2.82 HPE Synergy 620 Gen9 Compute Module - Prior to iLO 4 v2.82 HPE Synergy 480 Gen9 Compute Module - Prior to iLO 4 v2.82 HPE StoreEasy 1860 Performance Storage - Prior to iLO 5 v2.78 HPE StoreEasy 1660 Performance Storage - Prior to iLO 5 v2.78 HPE StoreEasy 1660 Expanded Storage - Prior to iLO 5 v2.78 HPE StoreEasy 1560 Storage - Prior to iLO 5 v2.78 HPE StoreEasy 1660 Storage - Prior to iLO 5 v2.78 HPE StoreEasy 1460 Storage - Prior to iLO 5 v2.78 HPE Storage File Controller - Prior to iLO 5 v2.78 HPE Storage Performance File Controller - Prior to iLO 5 v2.78 HPE Synergy 480 Gen10 Plus Compute Module - Prior to iLO 5 v2.78 HPE Synergy 480 Gen10 Compute Module - Prior to iLO 5 v2.78 HPE Synergy 660 Gen10 Compute Module - Prior to iLO 5 v2.78 HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis - Prior to iLO 5 v2.78 HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis - Prior to iLO 5 v2.78 HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis - Prior to iLO 5 v2.78 HPE Apollo n2600 Gen10 Plus - Prior to iLO 5 v2.78 HPE Apollo 4200 Gen10 Server - Prior to iLO 5 v2.78 HPE Apollo n2800 Gen10 Plus - Prior to iLO 5 v2.78 HPE Apollo 4510 Gen10 System - Prior to iLO 5 v2.78 HPE Apollo 4200 Gen10 Plus System - Prior to iLO 5 v2.78 HPE Apollo 6500 Gen10 System - Prior to iLO 5 v2.78 HPE Apollo 6500 Gen10 Plus System - Prior to iLO 5 v2.78 HPE Edgeline e920d Server Blade - Prior to iLO 5 v2.78 HPE Edgeline e920t Server Blade - Prior to iLO 5 v2.78 HPE Edgeline e920 Server Blade - Prior to iLO 5 v2.78 HPE ProLiant e910t Server Blade - Prior to iLO 5 v2.78 HPE ProLiant e910 Server Blade - Prior to iLO 5 v2.78 HPE ProLiant XL220n Gen10 Plus Server - Prior to iLO 5 v2.78 HPE ProLiant XL170r Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant XL230k Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant XL270d Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant XL290n Gen10 Plus Server - Prior to iLO 5 v2.78 HPE ProLiant XL450 Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant XL190r Gen10 Server - Prior to iLO 5 v2.78 HPE ProLiant XL675d Gen10 Plus Server - Prior to iLO 5 v2.78 HPE ProLiant XL645d Gen10 Plus Server - Prior to iLO 5 v2.78 HPE ProLiant XL225n Gen10 Plus 1U Node - Prior to iLO 5 v2.78 HPE StoreEasy 1860 Storage - Prior to iLO 5 v2.78 HPE StoreEasy 3840 Gateway Storage - Prior to iLO 4 v2.82 HPE StoreEasy 3840 Gateway Storage Blade - Prior to iLO 4 v2.82 HPE StoreEasy 3830 Gateway Storage - Prior to iLO 4 v2.82 HPE StoreEasy 3830 Gateway Storage Blade - Prior to iLO 4 v2.82 HPE StoreEasy 1840 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1830 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1640 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1630 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1540 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1530 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1440 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1430 Storage - Prior to iLO 4 v2.82 HPE StoreVirtual 3000 File Controller - Prior to iLO 4 v2.82 HPE StoreEasy 3850 Gateway Single Node Upgrade - Prior to iLO 4 v2.82 HPE StoreEasy 3850 Gateway Storage - Prior to iLO 4 v2.82 HPE StoreEasy 3850 Gateway Storage Blade - Prior to iLO 4 v2.82 HPE StoreEasy 1850 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1650 Expanded Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1650 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1550 Storage - Prior to iLO 4 v2.82 HPE StoreEasy 1450 Storage - Prior to iLO 4 v2.82 HPE 3PAR StoreServ File Controller - Prior to iLO 4 v2.82 HPE 3PAR StoreServ File Controller v2 Storage - Prior to iLO 4 v2.82 HPE 3PAR StoreServ File Controller v3 System - Prior to iLO 4 v2.82 HPE Apollo 4200 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant WS460c Gen8 Graphics Server Blade - Prior to iLO 4 v2.82 HPE ProLiant WS460c Gen9 Graphics Server Blade - Prior to iLO 4 v2.82 HPE ProLiant MicroServer Gen8 - Prior to iLO 4 v2.82 HPE ProLiant ML110 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL170r Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL190r Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL220a Gen8 v2 Server - Prior to iLO 4 v2.82 HPE ProLiant XL230b Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL230a Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL250a Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL270d Gen9 Special Server - Prior to iLO 4 v2.82 HPE ProLiant XL450 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL730f Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL740f Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant XL750f Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant SL210t Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant SL230s Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant SL250s Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant SL270s Gen8 SE Server - Prior to iLO 4 v2.82 HPE ProLiant SL270s Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant ML30 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant ML310e Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant ML310e Gen8 v2 Server - Prior to iLO 4 v2.82 HPE ProLiant ML350e Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant ML350e Gen8 v2 Server - Prior to iLO 4 v2.82 HPE ProLiant ML350p Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant ML350 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL20 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL60 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL80 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL120 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL160 Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL160 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL180 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL320e Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL320e Gen8 v2 Server - Prior to iLO 4 v2.82 HPE ProLiant DL360e Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL360p Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL360 Gen9 Server - Prior to iLO 4 v2.82 HPE Apollo r2000 Chassis - Prior to iLO 5 v2.78 HPE ProLiant DL380e Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL380p Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL380 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL385p Gen8 (AMD) - Prior to iLO 4 v2.82 HPE ProLiant DL560 Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL560 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant DL580 Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant DL580 Gen9 Server - Prior to iLO 4 v2.82 HPE ProLiant BL420c Gen8 Server - Prior to iLO 4 v2.82 HPE ProLiant BL460c Gen8 Server Blade - Prior to iLO 4 v2.82 HPE ProLiant BL460c Gen9 Server Blade - Prior to iLO 4 v2.82 HPE ProLiant BL465c Gen8 Server Blade - Prior to iLO 4 v2.82 HPE ProLiant BL660c Gen8 Server Blade - Prior to iLO 4 v2.82 HPE ProLiant BL660c Gen9 Server - Prior to iLO 4 v2.82 BACKGROUND HPE calculates CVSS using CVSS Version 3.1. If the score is provided from NIST, we will display Version 2.0, 3.0, or 3.1 as provided from NVD. Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2023-28083 CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L 8.3 (AV:A/AC:L/Au:S/C:C/I:C/A:N) 7.1 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 Hewlett Packard Enterprise would like to acknowledge Jakub Brzozowski (redfr0g) with STM Cyber Sp. z o.o. for reporting these vulnerabilities to security-alert@hpe.com. RESOLUTION HPE has made the following software updates and mitigation information to resolve the vulnerability in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE Integrated Lights-Out 6 (iLO 6) v1.20 and later for: ProLiant Gen11 servers. HPE Integrated Lights-Out 5 (iLO 5) v2.78 and later for: ProLiant Gen10 and Gen10 Plus servers. Synergy compute modules. Apollo chassis, servers, and systems. Converged systems. StoreEasy Storage. HPE Integrated Lights-Out 4 (iLO 4) v2.82 and later for: ProLiant Gen8 and Gen9 servers. Synergy compute modules. Apollo chassis and servers Converged systems. StoreEasy Storage. 3PAR StoreServ Controllers. Please visit the HPE Support Center to download the latest firmware: HPE Integrated Lights-Out 6 (iLO 6) 1.20 and later. HPE Integrated Lights-Out 5 (iLO 5) 2.78 and later. HPE Integrated Lights-Out 4 (iLO 4) 2.82 and later. HISTORY Version:1 (rev.1) - 13 March 2023 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HPE has made the following software updates and mitigation information to resolve the vulnerability in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE Integrated Lights-Out 6 (iLO 6) v1.20 and later for: ProLiant Gen11 servers. HPE Integrated Lights-Out 5 (iLO 5) v2.78 and later for: ProLiant Gen10 and Gen10 Plus servers. Synergy compute modules. Apollo chassis, servers, and systems. Converged systems. StoreEasy Storage. HPE Integrated Lights-Out 4 (iLO 4) v2.82 and later for: ProLiant Gen8 and Gen9 servers. Synergy compute modules. Apollo chassis and servers Converged systems. StoreEasy Storage. 3PAR StoreServ Controllers. Please visit the HPE Support Center to download the latest firmware: HPE Integrated Lights-Out 6 (iLO 6) 1.20 and later. HPE Integrated Lights-Out 5 (iLO 5) 2.78 and later. HPE Integrated Lights-Out 4 (iLO 4) 2.82 and later. HISTORY Version:1 (rev.1) - 13 March 2023 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...