Description:

Info

Document ID: hpesbnw04018en_us Version: 1 HPESBNW04018 rev.1 - HPE Aruba Clearpass Manager, Information Disclosure in Web Management Interface for Aruba Intelligent Edge Switches NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2020-07-22 Last Updated: 2020-07-23 Potential Security Impact: Remote: Unauthorized Information Disclosure Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY HPE has resolved vulnerabilities in Aruba Clearpass Manager. This information was alerted in https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2020-001.txt Advisory ID: ARUBA-PSA-2020-001 CVE: CVE-2019-5322 Publication Date: 2020-Feb-12Status: ConfirmedRevision: 2 Information Disclosure in Web Management Interface for Aruba Intelligent Edge Switches. An information disclosure vulnerability is present in Aruba Intelligent Edge Switches which allows an attacker to retrieve sensitive system information. This attack can be carried out without user authentication under very specific conditions. This vulnerability affects Aruba Intelligent Edge Switches: 5400R3810292029302530 with GigT Port2530 10/100 port2540 The following firmware versions for the aforementioned products are affected: 16.08. before 16.08.000916.09. before 16.09.000716.10. before 16.10.0003 An information disclosure vulnerability exists in the web management interface for affected switches. This vulnerability could be used to retrieve sensitive system information by sending a specially crafted packet to the Web Management Interface. The vulnerability can only be exploited to retrieve system information under very specific conditions. If those conditions are met, the vulnerability can be exploited without authentication. Internal reference: ASIRT-89Severity: HIGHCVSSv3 Overall Score: 7.5 CVSS Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N This vulnerability is resolved by updating to the following firmware versions: - 16.08.0009 - 16.09.0007 - 16.10.0003 Aruba would like to thank the following researcher for discovering andreporting this vulnerability: Alexis La Goutte If updating to the latest version is not possible, disable web management where possible. If you need assistance disabling web management, contact Aruba support. Another workaround is isolating the switch web management interface using network segmentation techniques. Aruba is not aware of any public discussion or exploit code related to this issue. Revision 1 / 2020-Feb-11 / Initial Release Revision 2 / 2020-Feb-12 / Additional Workaround Information References: PSRT111176 CVE-2019-5322 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. Aruba 2540 Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 2530 Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 2930F Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 2930M Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 2920 Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 3810M Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 Aruba 5400R zl2 Switch Series 16.08.* before 16.08.0009 16.09.* before 16.09.0007 16.10.* before 16.10.0003 BACKGROUND HPE calculates CVSS using CVSS Version 3.1. If the score is provided from NIST, we will display Version 2.0, 3.0, or 3.1 as provided from NVD. Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2019-5322 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) 7.5 (AV:N/AC:L/Au:N/C:P/I:N/A:N) 5 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 RESOLUTION HPE Aruba has provided the following updated to resolve the issues: This vulnerability is resolved by updating to the following firmware versions: 16.08.0009 16.09.0007 16.10.0003 HISTORY Version:1 (rev.1) - 22 July 2020 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HPE Aruba has provided the following updated to resolve the issues: This vulnerability is resolved by updating to the following firmware versions: 16.08.0009 16.09.0007 16.10.0003 HISTORY Version:1 (rev.1) - 22 July 2020 Initial release Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive