Hewlett Packard Enterprise | hpesbst04384en_us

HPESBST04384 rev.2 - HPE B-series SAN Switches with Brocade Fabric OS (FOS), Remote Authentication Bypass

Last update date:

2/28/2024

Affected products:

Brocade 16Gb Fibre Channel SAN Switch for HPE Synergy

Brocade 32Gb Fibre Channel SAN Switch for HPE Synergy

Brocade 16Gb SAN Switch for HPE BladeSystem c-Class

Brocade 8Gb SAN Switch for HPE BladeSystem c-Class

HPE 1606 Extension SAN Switch

HPE 8/24 SAN Switch

HPE 8/8 SAN Switch

HPE B-series SN6000B Fibre Channel Switch

HPE B-series SN6500B Fibre Channel Switch

HPE SN3000B Fibre Channel Switch

HPE Storage Fibre Channel Switch B-series SN3600B

HPE Storage Fibre Channel Switch B-series SN6600B

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Info

Document ID: hpesbst04384en_us Version: 2 HPESBST04384 rev.2 - HPE B-series SAN Switches with Brocade Fabric OS (FOS), Remote Authentication Bypass NOTICE: The information in this Security Bulletin should be acted upon as soon as possible. Release Date: 2022-11-10 Last Updated: 2022-11-18 Potential Security Impact: Remote: Authentication Bypass, Unqualified Configuration Change Source: Hewlett Packard Enterprise, HPE Product Security Response Team VULNERABILITY SUMMARY A potential security vulnerability has been identified in HPE SAN switches with the below Brocade Fabric OS (FOS) versions. v9.1 prior to v9.1.1_01 v9.0 prior to v9.0.1e1 v8.2 prior to v8.2.3c1 v7.4 prior to v7.4.2j1 This vulnerability could be remotely exploited to bypass authentication and perform unauthorized configuration changes References: CVE-2022-33186 SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HPE SN8000B 4-slot SAN Director Switch - v8.x prior to v8.2.3c1 HPE SN8000B 8-slot SAN Director Switch - v8.x prior to v8.2.3c1 HPE SN8600B 4-slot SAN Director Switch - v9.1.x prior to v9.1.1_01, v9.0.x prior to v9.0.1e1 and v8.x prior to v8.2.3c1 HPE SN8600B 8-slot SAN Director Switch - v9.1.x prior to v9.1.1_01, v9.0.x prior to v9.0.1e1 and v8.x prior to v8.2.3c1 HPE SN8700B 4-slot SAN Director Switch - v9.1.x prior to v9.1.1_01 and v9.0.x prior to v9.0.1e1 HPE SN8700B 8-slot SAN Director Switch - v9.1.x prior to v9.1.1_01 and v9.0.x prior to v9.0.1e1 HPE SN3000B Fibre Channel Switch - v8.x prior to v8.2.3c1 HPE B-series SN3600B Fibre Channel Switch - v9.1.x prior to v9.1.1_01, v9.0.x prior to v9.0.1e1 and v8.x prior to v8.2.3c1 HPE B-series SN6000B Fibre Channel Switch - v8.x prior to v8.2.3c1 HPE B-series SN6500B Fibre Channel Switch - v8.x prior to v8.2.3c1 HPE B-series SN6600B Fibre Channel Switch - v9.1.x prior to v9.1.1_01, v9.0.x prior to v9.0.1e1 and v8.x prior to v8.2.3c1 HPE B-series SN6650B Fibre Channel Switch - v9.1.x prior to v9.1.1_01, v9.0.x prior to v9.0.1e1 and v8.x prior to v8.2.3c1 HPE B-series SN6700B Fibre Channel Switch - v9.1.x prior to v9.1.1_01 and v9.0.x prior to v9.0.1e1 HPE B-series SN6750B Fibre Channel Switch - v9.1.x prior to v9.1.1_01 HPE B-series SN2600B SAN Extension Switch - v9.1.x prior to v9.1.1_01 and v9.0.x prior to v9.0.1e1 HPE B-series SN4000B SAN Extension Switch - v8.x prior to v8.2.3c1 HPE 8/24 SAN Switch - v7.x prior to v7.4.2j1 HPE 8/8 SAN Switch - v7.x prior to v7.4.2j1 HPE 1606 Extension SAN Switch - v7.x prior to v7.4.2j1 Brocade 8Gb SAN Switch for HPE BladeSystem c-Class - v7.x prior to v7.4.2j1 Brocade 16Gb SAN Switch for HPE BladeSystem c-Class - v8.x prior to v8.2.3c1 Brocade 16Gb/12 Fibre Channel SAN Switch Module for HPE Synergy - v8.x prior to v8.2.3c1 Brocade 16Gb/24 Fibre Channel SAN Switch Module for HPE Synergy - v8.x prior to v8.2.3c1 Brocade 32Gb Fibre Channel SAN Switch for HPE Synergy - v9.1.x prior to v9.1.1_01 and v9.0.x prior to v9.0.1e1 BACKGROUND HPE calculates CVSS using CVSS Version 3.1. If the score is provided from NIST, we will display Version 2.0, 3.0, or 3.1 as provided from NVD. Reference V3 Vector V3 Base Score V2 Vector V2 Base Score CVE-2022-33186 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H 8.1 (AV:A/AC:L/Au:N/C:N/I:C/A:C) 7.8 Information on CVSS is documented in HPE Customer Notice: HPSN-2008-002 RESOLUTION HPE has made the following firmware updates available to resolve the vulnerabilities in HPE SAN Switches with Brocade Fabric OS (FOS). Please visit the HPE Support Center to download the latest software: Version 9.1.1_01 or later FOS firmware for HPE B-Series products Version 9.0.1e1 or later FOS firmware for HPE B-Series products Version 8.2.3c1 or later FOS firmware for HPE B-Series products Version 7.4.2j1 or later FOS firmware for HPE B-Series products Workaround Customers may consider the below workaround where an update is not feasible. To remove any exposure to this vulnerability, Brocade Fabric OS (FOS) switch administrators must disable EZServer support. Disabling EZServer is accomplished through the use of the CLI command configurechassis. Disabling the EZServer in the switch configuration will prevent any exposure to this vulnerability. This option is only available on Brocade Fabric OS versions v8.1.0b and higher. Customers running on older versions of Brocade Fabric OS, including v7.4.2j, do not have this option and must upgrade to Brocade Fabric OS v7.4.2j1 to protect their switches. Example showing how to disable the EZServer module: brocadeswitch:admin> configurechassis Configure... cfgload attributes (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] webtools attributes (yes, y, no, n): [no] y ... Login Session Timeout (in secs): (60..432000) [7200] EZserver Enabled (yes, y, no, n): [yes] no ... brocadeswitch:admin > Notes: The following actions will re-enable EZServer on Brocade Fabric OS versions that do not have the EZServer module entirely removed. firmwarecleaninstall config removall configdefault factory reset HISTORY Version:1 (rev.1) - 15 November 2022 Initial release Version:2 (rev.2) - 18 November 2022 Added workaround to disable the EZServer module Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive System management and security procedures must be reviewed frequently to maintain system integrity. HPE is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. "HPE is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HPE products the important security information contained in this Bulletin. HPE recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HPE does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HPE will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HPE disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement." ©Copyright 2024 Hewlett Packard Enterprise Development LP Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Scope

None

Resolution

HPE has made the following firmware updates available to resolve the vulnerabilities in HPE SAN Switches with Brocade Fabric OS (FOS). Please visit the HPE Support Center to download the latest software: Version 9.1.1_01 or later FOS firmware for HPE B-Series products Version 9.0.1e1 or later FOS firmware for HPE B-Series products Version 8.2.3c1 or later FOS firmware for HPE B-Series products Version 7.4.2j1 or later FOS firmware for HPE B-Series products Workaround Customers may consider the below workaround where an update is not feasible. To remove any exposure to this vulnerability, Brocade Fabric OS (FOS) switch administrators must disable EZServer support. Disabling EZServer is accomplished through the use of the CLI command configurechassis. Disabling the EZServer in the switch configuration will prevent any exposure to this vulnerability. This option is only available on Brocade Fabric OS versions v8.1.0b and higher. Customers running on older versions of Brocade Fabric OS, including v7.4.2j, do not have this option and must upgrade to Brocade Fabric OS v7.4.2j1 to protect their switches. Example showing how to disable the EZServer module: brocadeswitch:admin> configurechassis Configure... cfgload attributes (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] webtools attributes (yes, y, no, n): [no] y ... Login Session Timeout (in secs): (60..432000) [7200] EZserver Enabled (yes, y, no, n): [yes] no ... brocadeswitch:admin > Notes: The following actions will re-enable EZServer on Brocade Fabric OS versions that do not have the EZServer module entirely removed. firmwarecleaninstall config removall configdefault factory reset HISTORY Version:1 (rev.1) - 15 November 2022 Initial release Version:2 (rev.2) - 18 November 2022 Added workaround to disable the EZServer module Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy. Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com. Report: To report a potential security vulnerability for any HPE supported product: Web Form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com Hewlett Packard Enterprise Product Security Response Policy: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00100637en_us Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive

Additional Resources / Links