Microsoft SQL Server | 2268493

Fixes an issue where restoring an In-Memory OLTP database backup that has Transparent data encryption (TDE) enabled fails and returns the following error message: Error: 33126, Severity: 16, State: 1. Database encryption key is corrupted and cannot be read. Note: To apply this fix, you need to enable a trace flag (TF) to relax TDE checks for In-Memory tables and disable the TF after the restoration is completed. For more information, contact Microsoft Customer Service and Support.

Last update date:

6/15/2023

Affected products:

SQL Server 2022 on Linux

SQL Server 2022 on Windows

Affected releases:

build lower than 16.0.4045.3

Fixed releases:

16.0.4045.3

Description:

Fixes an issue where restoring an In-Memory OLTP database backup that has Transparent data encryption (TDE) enabled fails and returns the following error message: Error: 33126, Severity: 16, State: 1. Database encryption key is corrupted and cannot be read. Note: To apply this fix, you need to enable a trace flag (TF) to relax TDE checks for In-Memory tables and disable the TF after the restoration is completed. For more information, contact Microsoft Customer Service and Support.