Operational Defect Database

BugZero found this defect 249 days ago.

Microsoft SQL Server | 2606680

Fixes the following error 2570 that you encounter when you run DBCC CHECKDB against a database, which is caused by using negative parameters in the RANDOM function against a column that uses dynamic data masking (DDM): Msg 2570, Level 16, State 3, Line <LineNumber> Page (<PageID>), slot <SlotID> in object ID <ObjectID>, index ID <IndexID>, partition ID <PartitionID>, alloc unit ID <UnitID> (type "<Type>"). Column "<ColumnName>" value is out of range for data type "<DataType>". Update column to a legal value.

Last update date:

9/14/2023

Affected products:

SQL Server 2022 on Linux

SQL Server 2022 on Windows

Affected releases:

build lower than 16.0.4075.1

Fixed releases:

16.0.4075.1

Description:

Fixes the following error 2570 that you encounter when you run DBCC CHECKDB against a database, which is caused by using negative parameters in the RANDOM function against a column that uses dynamic data masking (DDM): Msg 2570, Level 16, State 3, Line <LineNumber> Page (<PageID>), slot <SlotID> in object ID <ObjectID>, index ID <IndexID>, partition ID <PartitionID>, alloc unit ID <UnitID> (type "<Type>"). Column "<ColumnName>" value is out of range for data type "<DataType>". Update column to a legal value.

Additional Resources / Links