Palo Alto Networks | PAN-179966

Fixed an issue where, after upgrading to a PAN-OS 8.1 release, the port on the firewall stayed up, but the port on the connected device reported down. This occurred because, on force mode, autoneg was disabled by default. With this fix, autoneg is enabled by default on force mode.

Last update date:

5/16/2024

Affected products:

Pan OS

Affected releases:

No affected releases provided.

Fixed releases:

10.2.1

Description:

The earliest recollection of this bug is traced back to PAN-OS 10.2.1 - May 16, 2024. This bug is fixed in PAN-OS versions 10.2.1. Fixed an issue where, after upgrading to a PAN-OS 8.1 release, the port on the firewall stayed up, but the port on the connected device reported down. This occurred because, on force mode, autoneg was disabled by default. With this fix, autoneg is enabled by default on force mode. For more information: https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-1-known-and-addressed-issues/pan-os-10-2-1-addressed-issues