Operational Defect Database

BugZero updated this defect 4 days ago.

Palo Alto Networks | PAN-200946

Fixed an issue with firewalls in active/passive HA configurations where GRE tunnels went down due to recursive routing when the passive firewall was booting up. When the passive firewall became active and no recursive routing was configured, the GRE tunnel remained down.

Last update date:

5/15/2024

Affected products:

Pan OS

Affected releases:

No affected releases provided.

Fixed releases:

10.2.3

10.2.4

10.1.9

Description:

The earliest recollection of this bug is traced back to PAN-OS 10.1.9 - May 15, 2024. This bug is fixed in PAN-OS versions 10.2.3, 10.2.4, 10.1.9. Fixed an issue with firewalls in active/passive HA configurations where GRE tunnels went down due to recursive routing when the passive firewall was booting up. When the passive firewall became active and no recursive routing was configured, the GRE tunnel remained down. For more information: https://docs.paloaltonetworks.com/pan-os/10-1/pan-os-release-notes/pan-os-10-1-9-known-and-addressed-issues/pan-os-10-1-9-addressed-issues https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-3-known-and-addressed-issues/pan-os-10-2-3-h2-addressed-issues https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-4-known-and-addressed-issues/pan-os-10-2-4-addressed-issues

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Addressed

Learn More