Veeam | kb1168

Enterprise Manager works with http, but not with https

Last update date:

5/6/2022

Affected products:

Veeam Backup & Replication

Affected releases:

ALL

Fixed releases:

No fixed releases provided.

Description:

Challenge

Enterprise Manager webpage inaccessible via HTTP and HTTPSor The Enterprise Manager is accessible via HTTP, but not via HTTPS.

Solution

Enterprise Manager webpage inaccessible via HTTP and HTTPS Check the following on the Machine where the browser is running: Clear the browser's cache and cookies, or try accessing the Enterprise Manager page using the browser's Private/Incognito mode. Test if the machine can reach the Enterprise Manager web ports. The default ports are 9080 and 9443.   Check the following on the Enterprise Manager server itself Make sure that the Veeam Backup Enterprise Manager service is running.