Veeam | kb1477

VMware Objects are not visible in Ops Mgr

Last update date:

11/17/2020

Affected products:

Veeam Management Pack for Microsoft System Center

Affected releases:

8.0

Fixed releases:

No fixed releases provided.

Description:

Challenge

1. No virtual infrastructure objects (Clusters, Hosts, VMs etc) appear in the OpsMgr Console. Additionally you may receive an alert in Ops Mgr from the nworks Collector as follows:   Alert Name: Agent proxying needs to be enabled for a health service to submit discovery data about other computers. Alert description (example): Details:Health service ( [server name] ) should not generate data about this managed type ( nworks.VMware.VEM.VMGUEST ) object Id ( A2A3BA11-F03D-6757-597A-28A35B5000FE ). Note: the alert description will contain server names and object IDs specific to your own environment.   2. Updates to the virtual infrastructure (such as adding or removing Cluster, Host, or VMs) are not reflected in the Ops Mgr views.

Cause

1. Proxying must be enabled for any server (agent or management server) where the nWorks Collector is running. This setting allows the Collector, via Ops Mgr agent, to inject new objects (such as ESX Hosts and VMs) into Ops Mgr. 2. Updates to VMware systems (such as add/remove an ESX host) may not have been reflected in Ops Mgr due to discovery synchronization or other issue.

Solution

1. Verify Proxy Settings Verify that the Proxy setting has been enabled for the server where the nWorks Collector is installed. 1. In the OpsMgr console, verify the Proxy settings. Go to the Administration pane. a. If the Collector is running on a standard Ops Mgr agent, then browse to Device Management | Agent Managed and select the Collector server. b. If the Collector is running on an Ops Mgr Management server, then browse to Device Management | Management Servers and select the Collector server. 2.  Double-click the relevant server, click the Security tab and ensure that the ‘Allow this agent to act as a proxy and discover managed objects on other computers’ check box is selected.   2. Rebuild Topology   If only certain VMware systems items are missing or have not been updated in Ops Mgr, then it may be required to trigger a topology rediscovery. This is accomplished with the Rebuild Full Topology function available in the Veeam MP UI. Rebuild is available at global Veeam Extensions level (where all Collectors will rebuild). After clicking this button you must wait several collection cycles (a cycle is 5 minutes by default) for the rebuild to complete.

More Information

Check out our other Resources for more information (User Guides, Release Notes, etc.). - http://www.veeam.com/vmware-microsoft-esx-monitoring/resources.html

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More

Search:

...