Changing the number of displayed alarms in the Veeam ONE Monitor client

Last update date:

5/26/2021

Affected products:

Veeam ONE

Affected releases:

9.0

Fixed releases:

No fixed releases provided.

Description:

Challenge

When you resize your Veeam ONE Monitor client on the big screens, the number of displayed alarms does not change.

Cause

The predefined Veeam ONE settings allow viewing 13 alarms on one page only.

Solution

In order to change the number of displayed alarms, follow these steps:1. Log onto the server where Veeam ONE Monitor console is installed and open the registry editor (regedit) snap-in.2. Navigate to the following registry path: HKEY_CURRENT_USER\SOFTWARE\Veeam\Veeam ONE Monitor 3. Modify (or add if not already present) the value in this location: Name:  MaxAlarmsPerPageType:   DWORDBase:   DecimalValue:  Specify the value that suits your requirements (the default value is 13). 4. Reopen your Veeam ONE Monitor client to see the changes.

More Information

Should you have any questions, contact Veeam Support.