Veeam Marks a Data Tape as a Cleaning Tape

Last update date:

4/8/2022

Affected products:

Veeam Backup & Replication

Affected releases:

ALL

Fixed releases:

No fixed releases provided.

Description:

Challenge

One or more non-cleaning tape cartridges have become marked as cleaning tapes and may not appear in the Veeam Backup & Replication console.

Cause

Cause 1: CLN Barcodes Per the LTO barcode standard, a barcode that begins with the prefix CLN is considered a cleaning tape. If for some reason, barcodes with the prefix CLN are attached to tapes intended for storing data, Veeam Backup & Replication will mark these tapes as cleaning tapes. Resolution: If non-cleaning cartridges have inadvertently had barcodes with the prefix CLN attached to them, the barcode stickers must be replaced with appropriate barcodes.

Solution

If the documented causes listed in this article do not apply, please do the following: Collect logs from Veeam Backup & Replication using the 'Export all logs for selected components', selecting the Veeam Backup Server and the relevant Tape Server. (Optional, but highly recommended) Stop all jobs or wait until all jobs have stopped, then back up the Veeam Backup & Replication Configuration database. Create a new Veeam Support case referencing KB2789. Attach to the case the logs from Step 1 and the database from Step 2.

More Information

If an actual cleaning tape is inserted into the Tape Libary and it does not appear within Veeam Backup & Replication, check if the Tape Library has been configured to have a dedicated cleaning tape slot. Most Tape Hardware vendors intend for these dedicated cleaning tape slots to be used when the Library itself will manage the cleaning routines. As such, these Cleaning Slots are not presented to backup applications. If Veeam Backup & Replication will be used to manage the tape drive cleaning routines, the cleaning tape should be inserted into a storage slot. Cleaning Tapes must have the appropriate barcode with the prefix CLN for Veeam Backup & Replication to recognize them as cleaning tapes.