Operational Defect Database

BugZero found this defect 1469 days ago.

Veeam | kb3172

Veeam Management Pack 8.0 Update 6 cumulative patch for VMware vSphere 7.0 monitoring

Last update date:

4/7/2021

Affected products:

No affected products provided.

Affected releases:

Fixed releases:

No fixed releases provided.

Description:

Challenge

Veeam Management Pack 8.0 Update 6 is not compatible with VMware vSphere 7.0 (and later). When you try to connect to vCenter Servers running VMware vSphere 7.0, you get the following error: "Cannot connect to "YourVcenterName" on port 443. Unsupported API version."

Cause

The issue is related to the API changes in VMware vSphere 7.0

Solution

The Veeam Management Pack 8.0 Update 6 cumulative patch for VMware vSphere 7.0 monitoring provides the compatibility with VMware vSphere 7.0. The patch also addresses several minor issues and requests related to the monitoring of vSphere 7 and earlier versions that were reported to Veeam Technical Support. The list of improvements includes: Support for VMware vSphere 7.0 APIs. A fix for the issue with relation data being collected incompletely from virtual switches in environments running VMware vSphere 6.x and earlier versions. A fix for the issue with the datastore unknown files metric being collected incorrectly. A new property for the Datastore Container object to represent the relation with the Veeam Virtualization Extensions Service server that manages the Veeam Collector processing a specific Datastore Container. A fix for the data collection issue when monitoring standalone VMware ESXi 7.0 hosts To install the cumulative patch, perform the following steps: Make sure you are running Veeam Management Pack 8.0 Update 6 (build 8.0.0.2467). For more information, see this Veeam KB article: https://www.veeam.com/kb2706. Unzip the archive. Run the VeeamMP80_Update6_CP2.exe file on all machines where Veeam components are installed (Veeam Virtualization Extensions Service, Veeam Collector, Veeam Virtualization Extensions Service UI) and follow the wizard instructions. The Veeam Collector will be upgraded to build 8.0.0.2480. The Veeam Virtualization Extensions Service and Veeam Virtualization Extensions Service UI will preserve build 8.0.0.2218.

More Information

DOWNLOAD CUMULATIVE PATCHMD5: 68D9AA00E192599200FD64462388E74ASHA-1: 4DF27F4B8FAC68AEC723F8F9112C28EBD41D22B5NOTE: The Veeam Management Pack 8.0 Update 6 cumulative patch for Veeam Backup & Replication monitoring is available in the following KB article:https://www.veeam.com/kb2940   Should you have any questions, contact Veeam Support.