Operational Defect Database

BugZero found this defect 1213 days ago.

Veeam | kb4093

Cisco HyperFlex & Veeam CDP support status

Last update date:

11/18/2021

Affected products:

Veeam Backup & Replication

Affected releases:

11

Fixed releases:

No fixed releases provided.

Description:

Challenge

Cisco HyperFlex VM Snapshot creation process will stop VMs if a Veeam CDP storage policy filter is present. Affected VMs will not boot anymore.

Cause

Each time a Cisco HyperFlex Snapshot is created when a Veeam CDP storage policy filter is present, the HyperFlex snapshot creation process will change the ddb.sidecars entry within the vmdk metadata file so that it references a non-existent vmfd file.

Solution

Upgrade Cisco HX to prevent this from occuring Veeam RnD has confirmed that this issue is resolved in Cisco HX 4.5(2a) when used with vSphere 7.0 U2. Updating will prevent this issue from occurring but does not resolve it if it has happened.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More