Veeam | kb4168

VeeamCDP I/O filter cannot be installed "Error: the operation is not allowed in the current state"

Last update date:

5/19/2021

Affected products:

Veeam Backup & Replication

Affected releases:

11

Fixed releases:

No fixed releases provided.

Description:

Challenge

The installation of the Veeam CDP I/O Filter fails during deployment with the following error:

Cause

Veeam Support has determined that this issue is most frequently related to a DNS resolution failure.

Solution

All servers involved in the I/O Filter installation, Veeam server, vCenter, and ESXi host(s), must be able to resolve each other via FQDN.

More Information

Other requirements can be found here https://helpcenter.veeam.com/docs/backup/vsphere/cdp_requirements.html