Operational Defect Database

BugZero found this defect 930 days ago.

Veeam | kb4234

Veeam ONE version 10/10a impact on VMware vSAN

Last update date:

11/3/2021

Affected products:

Veeam ONE

Affected releases:

10

Fixed releases:

No fixed releases provided.

Description:

Challenge

The API calls used by Veeam ONE version 10/10a to collect vSAN performance data may impact vSAN health and performance in some environments.

Solution

Upgrade Veeam ONE to version 11 or later. Starting with Veeam ONE v11, a new collection method was implemented to prevent this issue.

More Information

For environments where Veeam ONE cannot be upgraded This registry value is only to be used with Veeam ONE versions 10 or 10a. The following registry value can be used to force Veeam ONE v10 or v10A to use an alternate vSAN data collection method to mitigate vSAN impact. Create the following registry value on the Veeam ONE server. Key Location: HKLM\SOFTWARE\Veeam\Veeam ONE Monitor\Service\ Value Name: VsanLowLevelApi Value Type: DWORD (32-Bit) Value Value Data: 0 Restart the Veeam ONE services afterward.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More