Operational Defect Database

BugZero found this defect 871 days ago.

Veeam | kb4266

A specified parameter was not correct: spec.vmProfile

Last update date:

8/3/2023

Affected products:

Veeam Backup & Replication

Affected releases:

11

Fixed releases:

No fixed releases provided.

Description:

Challenge

A Replication job fails with the following error:

Cause

This error occurs when the datastore selected for the restore operation or replication job is part of the VM Encryption Policy and the vCenter or vCloud Director in use does not fully support VM Encryption. More information is available here: VMware KB: "A specified parameter was not correct: spec.vmProfile" error when adding a new disk to a VM (78581)

Solution

To resolve this issue, select a Datastore from the Default Policy.