Operational Defect Database

BugZero found this defect 691 days ago.

Veeam | kb4333

Veeam's VSS Operations With SMB 3.0 Impacted by Windows June 14, 2022 Update

Last update date:

6/29/2022

Affected products:

Veeam Backup & Replication

Affected releases:

ALL

Fixed releases:

No fixed releases provided.

Description:

Challenge

After installing the Windows June 14,2022 update (KB5014702/KB5014746) on a Windows file server hosting SMB 3.0 shares, the follow Veeam Backup & Replication operations may be impacted: If those SMB 3.0 shares are added to Veeam Backup & Replication with the "Backup from Microsoft VSS snapshot" option enabled, the NAS Backup job(s) protecting those SMB 3.0 shares may fail with the following error: Failed to create a VSS snapshot Error: Failed to add volume [\\SMB3FS\SHARE1\] to the VSS snapshot set The given shadow copy provider does not support shadow copying the specified volume. --tr:Failed to add volumes to the snapshot set. --tr:Failed to perform pre-backup tasks. If those SMB 3.0 shares are used to store VMs for a Hyper-V host running Server 2012R2, the Backup job(s) for the VMs stored on those SMB 3.0 shares may fail with the following error: Failed to create snapshot (Fileshare Provider) (mode: Crash consistent) Details: Failed to add volume [\\SMB3FS\VOLUME1\] to the VSS snapshot set The given shadow copy provider does not support shadow copying the specified volume. --tr:Failed to add volumes to the snapshot set. --tr:Failed to perform pre-backup tasks.   When either type of job fails the following error will be found in the Windows Event Logs of the File Server hosting the SMB3.0 shares: Microsoft File Share Shadow Copy Agent Error: The client connecting to the FssAgent RPC server did not have Local Administrator or Backup Operator privilege on this machine.

Solution

NAS Backup Job Failure Review the following article from Microsoft: KB5015527: Shadow copy operations using VSS on remote SMB shares denied access after installing Windows update dated June 14, 2022 Specifically: Ensure that the June 14, 2022 update is installed on the following servers: File Server hosting the SMB 3.0 shares. The Veeam Backup Server. All Backup Proxies used by the NAS Backup job. Check the share permissions within Veeam Backup & Replication to ensure that Veeam has been configured to use a domain account that is a member of the Local Administrator or Backup Operator group on the File Server hosting the SMB 3.0 Shares.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More

Search:

...