Operational Defect Database

BugZero found this defect 676 days ago.

Veeam | kb4339

Veeam Recovery Orchestrator May Timeout During Execution of a Replica Plan if the Source vCenter Is Offline

Last update date:

7/21/2022

Affected products:

Veeam Recovery Orchestrator

Affected releases:

5.0

Fixed releases:

No fixed releases provided.

Description:

Challenge

When executing a Replica plan, Veeam Recovery Orchestrator may hang as it processes each VM in the plan. This hang will occur if two vCenters are used (one Production and one DR), and the source vCenter is down or otherwise unreachable. This issue only affects Replica plans.   The following Orchestration plans are not affected: CDP replica plans Restore plans Storage plans As this issue only affects Replica plans, the patch on this article is optional for Veeam Recovery Orchestrator deployments not using Replica plans.

Cause

This issue occurs due to a conflicting interaction between Veeam Recovery Orchestrator and the Veeam Backup PowerShell components.

Solution

Follow the steps below to install a patch to resolve this issue and prevent the hang condition.   Preparation: Before installing the patch, ensure that: there are no plans in an active state (e.g., failing over, halted, etc.). there are no plans running or scheduled to run. no datalab tests are running or scheduled to run. all Orchestrator agents on Veeam Backup servers have a "Healthy" status.

Download Information

Download VDRO Server Patch VAO.Server.x64_5.0.0.2782.msp

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More