Operational Defect Database

BugZero found this defect 257 days ago.

Veeam | kb4478

FC-Only Nimble Array Snapshot Failures in Veeam Backup & Replication P20230718

Last update date:

8/3/2023

Affected products:

Veeam Backup & Replication

Affected releases:

12

Fixed releases:

No fixed releases provided.

Description:

Challenge

When using Veeam Backup & Replication 12 P20230718, rescan, backup, and restore operations may fail when the Nimble array is configured to only use Fibre Channel (FC) protocol. The request could not be understood by the server. Unexpected argument 'multi_initiator'.

Solution

A private fix is available for Veeam Backup & Replication 12 P20230718 to resolve this issue; please create a Veeam Support case and mention this KB. Alternatively, set the Nimble storage protocol setting to "FC and iSCSI" to workaround the issue.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

cost-cta-background

Do you know how much operational outages are costing you?

Understand the cost to your business and how BugZero can help you reduce those costs.