Operational Defect Database

BugZero found this defect 80 days ago.

Veeam | kb4553

Backups to DDBoost Repository Fail After Upgrading to VBR 12.1.1

Last update date:

3/1/2024

Affected products:

Veeam Backup & Replication

Affected releases:

12.1

Fixed releases:

No fixed releases provided.

Description:

Challenge

Jobs or tasks interacting with a Dell Data Domain repository accessed using DD Boost failed after upgrading to Veeam Backup & Replication 12.1.1 with the following error: Failed to initialize DDBoost Library (Veeam.Backup.Common.CCppCOMException) in use. Err: 5012

Cause

This issue occurs because the Veeam Installer Service was unable to replace the existing VeeamDeploymentDll.dll with the newer one during the upgrade. When this occurs, the following error can be found within the C:\ProgramData\Veeam\Backup\Svc.VeeamInstaller.log log file: ERR |Failed to delete [C:\Windows\Veeam\Backup\old_12.0.0.1423_VeeamDeploymentDll.dll] file. >>  |boost::filesystem::remove: Access is denied: "C:\Windows\Veeam\Backup\old_12.0.0.1423_VeeamDeploymentDll.dll" >>  |An exception was thrown from thread [n/a]. Consequently, the old VeeamDeploymentDll.dll is unaware of the updated DD Boost library (libDDBoost.dll) included with Veeam Backup & Replication 12.1.1, which causes initialization errors.

Solution

Restart the machine assigned to as the Gateway Server for the Data Domain Repository. Alternatively, for larger environments where multiple Gateway Servers are present, Veeam Technical Support can provide a private fix (reference Issue ID 661804) that allows running a cmdlet to restart the Veeam Installer Service (VeeamDeploySvc) service on the Gateway Servers remotely.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Solved

Learn More

Search:

...