Operational Defect Database

BugZero updated this defect 58 days ago.

VMware | 325185

Smarts IP: Juniper M40e device CIP card shows "OTHER" status; How does Smarts determine the Card Status on a Juniper M40e device?

Last update date:

3/22/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

How does Smarts determine the Card Status on a Juniper M40e device?A CIP card on a Juniper M40e device is showing as "OTHER" status

Cause

Values of "online" (6) and "standby" (10) will produce "OK" values for the card status of the device. The value of "present" (3) will produce a status of "OTHER". This functionality is by design as a "present" status does not reflect the operational state of the card sufficiently to signify an "OK" status.

Resolution

The card status on a Juniper M40e device is determined from the OID 1.3.6.1.4.1.2636.3.1.15.1.8. This OID indicates the operational status of the submodule. Valid values for this OID include the following:unknown(1)empty(2)present(3)ready(4)announceOnlineonline(6)anounceOffline(7)offline(8)diagnostic(9)standby(10)