Operational Defect Database

BugZero updated this defect 67 days ago.

VMware | 338497

Receiving an error message when starting a Smarts mail notifier using the --conf= option.

Last update date:

3/22/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

Trying to start mail notifier using the --conf= option and receiving error error: GNA-E-EXTRAARGS-Extraneous arguments: '--conf=mail-notify.conf ...' GNA-ETRYHELP-Try 'sm_notify --help' for more information

Cause

The format being used for the command to start the notifier is: BASEDIR/smarts/bin/sm_notify mail --conf=<conf file name>

Resolution

The correct format to use to start the mail notifier using the --conf=<conf file name> option is: BASEDIR/smarts/bin/sm_notify --conf=<conf file name> mail

Related Information

This is true for all notifiers (mail, trap, file, and script). The type of the notifier should be the last argument passed on the command line as shown in the fix above.