BugZero updated this defect 33 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/16/2024
Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
Notification from traps display $V1$ in Event Text instead of the actual varbind information as in the following example: Authentication failure from host $V1$
The incoming trap is processed by a trap definition that is defined in trap_mgr.conf configuration file with EventText including $V1$. However, the incoming trap does not include any varbinds, so the EventText is taken literally, as $V1$ text.
To resolve this issue, do the following: Set up logging for the particular trap and verify whether the incoming trap includes the varbinds. To learn how to set up logging, see 8460 . Check the source of the notification and find the source device in the trap log. You may find the issue is only related to one or two devices. If the incoming trap is expected to include the varbinds in question, check the configuration of the SNMP Agent. Resolve the issue at the SNMP Agent side.