SMARTS undiscovered ICMPONLY devices are not added to Pending List

Last update date:

3/22/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

ICMPONLY devices not added to Pending List

Resolution

Setting the following parameter in :-<BASEDIR>/IP/smarts/local/conf/discovery/discovery.conf will cause ICMPONLY devices to be added to the Pending List:ShowPendingNONSNMP = TRUE

Related Information

Please note that setting the value to TRUE and having Auto-Discovery enabled can result in adding many hosts, workstations and other non-SNMP devices to the pending list.