BugZero updated this defect 33 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/16/2024
Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
IP tagging is not working in Smarts IPAll the correct configurations are set in the Tagging fields in the Polling and Thresholds screen
Setting change required in the Smarts IP discovery.conf configuration file.
To resolve this issue, do the following: Open the Smarts IP tpmgr-param.conf configuration file for editing using sm_edit as follows: <BASEDIR>/IP/smarts/bin/sm_edit conf/discovery/tpmgr-param.conf Ensure the following setting is made: DisableOverlappingIP FALSE Restart the Smarts IP domain to apply the change. The above fix applies to Smarts IP 7.0 and later