Operational Defect Database

BugZero updated this defect 58 days ago.

VMware | 357320

EMC SMARTS: ASL script failing with errors at line 1363115

Last update date:

3/22/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

ASL script failing with errors [23-May-2008 10:35:48+054ms IST] t@-1207109952 adapterASL-E-ERROR_RULE_INIT-While initializing rule set ASL-ERROR_FILE_PARSE-While parsing rules in file 'test.asl' <SYS>-ECHILD-No child processes; in file "" at line 1363115

Cause

The ASL script contains a line that is greater than 8200 characters long

Resolution

Modifying the ASL to use lines with a length of less than 8200 characters resolves this issue