Operational Defect Database

BugZero updated this defect 33 days ago.

VMware | 358382

Smarts SAM: Error "Bad entry in trap_mgr.conf" found in the trapd log file

Last update date:

4/16/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

The following error is found in the Smarts SAM trapd log file Bad entry in trap_mgr.conf

Cause

There is an invalid entry in the trap_mgr.conf configuration file found here: <BASEDIR>/smarts/bin/sm_edit conf/icoi/trap_mgr.conf The following is an example that can cause the "Bad entry" error: Invalid entry ElementName : $SYS$ Valid entry ElementName: $SYS$ Note the space in the invalid entry between the ElementName attribute and the semicolon (:). A space between the attribute name and the ":" is not allowed.

Resolution

To resolve this issue, find and correct the invalid entry in the trap_mgr.conf configuration file.